Model1452L
Turns Ratio2 : 1
Impedance Ratio4 : 1 (configurable)
Nominal Impedance2400 : 600 Ω
Primary DCR152 Ω + 152 Ω = 304 Ω
Secondary DCR54 Ω + 54 Ω = 108 Ω
Primary Inductance (100 Hz)60 H + 60 H ≈ 
Secondary Inductance10 H + 10 H
Core MaterialPermalloy 80%
Recommended Load600–2k Ω
  

Winding Configurations

  • Series–Series → 2:1    (Impedance ratio: 4:1, default)

  • Parallel–Parallel → 2:1  (Impedance ratio: 4:1, ¼ nominal Z)

  • Series–Parallel → 4:1   (Impedance ratio: 16:1)

  • Parallel–Series → 1:1   (Impedance ratio: 1:1)

 

Frequency Response

Extended bandwidth with vintage tonal weight.
Delivers clean headroom and gentle roll-off suited for preamp interfacing.

All measurements based on series–series winding configuration.

 

Includes triple EMI Faraday shielding and MuMetal magnetic protection for superior noise isolation.